Double Medical Sterilization Indicator Strip Eo/Steam/Plasma

Product Details
Customization: Available
Logo Printing: Without Logo Printing
Transport Package: Box/Carton
Still deciding? Get samples of US$ 0.01/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (15)
  • Double Medical Sterilization Indicator Strip Eo/Steam/Plasma
  • Double Medical Sterilization Indicator Strip Eo/Steam/Plasma
  • Double Medical Sterilization Indicator Strip Eo/Steam/Plasma
  • Double Medical Sterilization Indicator Strip Eo/Steam/Plasma
  • Double Medical Sterilization Indicator Strip Eo/Steam/Plasma
  • Double Medical Sterilization Indicator Strip Eo/Steam/Plasma
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Certifications
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Origin
China
HS Code
4821100000
Production Capacity
1300000 PCS Daily

Product Description

Product Description

 


Double Medical Sterilization Indicator Strip Eo/Steam/Plasma

Detailed Photos

Type I :STEAM/EO/PLASMA/FORM INDICATOR STRIP

Double Medical Sterilization Indicator Strip Eo/Steam/Plasma
 
STEAM Sterilization Indicator Strip
Standard: Complies with ISO11140 & EN867
Classify: Class4&class5&class6 
Sterilization color change  From Yellow turn to Black(after steam sterilization)
Sterilization Condition: Gravity displacement sterilizer: 121°C, 20 minutes
Pre-vacuum steam sterilizer:132 ~ 134 °C, 4~6 minutes.
Features: 1. Used to monitor sterilization exposure in steam sterilization processes.
2. The chemical indicator patch on the tape will change color:from yellow to black ---when exposed to steam sterilization processes to prove the pack has been sterilized
EO/FORM/PLAMSA Sterilization indicator Strip
Standard: Complies with ISO11140 & EN867
Style: Single/Double
Sterilization color change : 1.EO:Red to blue
2.FORM:Brown to Green
3.Plasma:Red to Yellow
Sterilization Condition: 1.EO
2.FORM
3.PLASMA
  1.Clear instructions and easy to read results
2.Immediate and accurate verification of load exposure to correct parameters of sterilization
(time, temperature and steam).
Double Medical Sterilization Indicator Strip Eo/Steam/Plasma
 

Type II:STEAM/ETO/FORM INDICATOR TAPE for medical packaging

DESCRIPTION ITEM NO SIZE PACK(PCS/CTN) COLOR CHANGE
Steam Indicator Tape GMST-1250 12mm*50m 76rolls/ctn Yellow turn to black(Under steam sterilization)
GMST-1950 19mm*50m 48rolls/ctn
GMST-2550 25mm*50m 36rolls/ctn
EO Indicator Tape GMET-1250 12mm*50m 76rolls/ctn Red turn to Green(Under EO gas sterilization
GMET-1950 19mm*50m 48rolls/ctn
GMET-2550 25mm*50m 36rolls/ctn
Plasma Indicator Tape GMPT-1250 12mm*50m 76rolls/ctn Blue turn to Wine-Red(Under plasma sterilization)
Double Medical Sterilization Indicator Strip Eo/Steam/Plasma
Double Medical Sterilization Indicator Strip Eo/Steam/Plasma
Double Medical Sterilization Indicator Strip Eo/Steam/Plasma

 

Type III:Bowie & Dick Test Packs

Sterilization principle 1.Bowie & Dick Test Pack was developed to control air removal and steam penetration performance in vacuum-assisted steam sterilizers. 
2.Bowie & Dick Test Packs are single-use devices that consist of a lead-free chemical indicator
3.BD Test Sheet, placed between porous sheets of paper, wrapped with crepe paper, with a Steam indicator label on the top of the package.  If the circle does not turn to a uniform black color, this is evidence of an imminent failure in the sterilizer, indicating that maintenance should be scheduled.
4.A uniform and complete color change on the BD Test Sheet indicates adequate air removal and steam penetration. A failure in air removal, poor quality steam, superheated steam and/ or non-condensable gases in steam supply are evidenced as a non-uniform color change in some areas of BD Test Sheet.
Useful tips: •  Bowie & Dick Test Pack should be used on a daily basis, every time the sterilizer is put into operation, before the first cycle and the first load to be sterilized. Start a shortened cycle (eg. omitting the phase of post-vacuum drying) to adequately heat up the sterilizer.
• Bowie-Dick Test Packs should be used daily; after a sterilizer is installed or relocated; after a sterilizer malfunction; after sterilization process failures; and after major repairs of the sterilizer.
•  Place the Bowie & Dick Test Pack horizontally with the chemical label facing up inside an empty chamber, on the bottom shelf or at the front of the sterilizer support and over the drain.
Bowie & Dick Test Pack are manufactured under ISO 11140 (Parts 1, 4 and 5) International Standards and elaborated under the Quality Management Systems ISO 13485 and ISO 9001.
Double Medical Sterilization Indicator Strip Eo/Steam/Plasma
Double Medical Sterilization Indicator Strip Eo/Steam/Plasma
Double Medical Sterilization Indicator Strip Eo/Steam/Plasma
Name: Autoclave Sterilization indicator BD bowie dick test pack for steam sterilization
Model: BD10
Size: 115*125mm
Material: steam penetration (air removal) barriers in the center
Feature: Bowie and dick test pack offered by us are single use test packs that allow users to successfully perform daily Bowie & Dick test in an effective & simple way. The advantages of single use test pack is that it is absolute safe in handling & reproducible in results. It consists of a series of steam penetration (air removal) barriers in the center of which is a chemical indicator sheet. Used for daily monitoring of pre-vacuum steam sterilizer. The Bowie Dick pack makes the operator a right control of the autoclave and verify possible defects during Bowie Dick's cycle. Bowie-Dick test packs should be used daily, especially after a sterilizer is installed, relocated, after sterilizer malfunction, after sterilization process failures, and after any major repairs of the sterilizer. Single use Bowie Dick pack is characterized by most reliable test such as:
1. Point out the presence of air leaks in the autoclave immediately and accurately;
2. Nontoxic ink and completely recycled materials;
3. Color Change: yellow to brown
These products are CE marked and meet the requirements of EN 867 and ISO 11140-1; Operation Condition: 134ºC, 3.5 minutes; 120ºC, 15 minutes
Certificate: CE/ISO13485

Certifications

Double Medical Sterilization Indicator Strip Eo/Steam/Plasma

Packaging & Shipping

Double Medical Sterilization Indicator Strip Eo/Steam/Plasma

Company Profile

 

Double Medical Sterilization Indicator Strip Eo/Steam/Plasma

FAQ

1) Q: How long for the production time ?
A: Normally production time of products is from 3 days to 15 days depending on the quantity ordered. If you need a rush order, contact our representatives to discuss your specific needs.

2). Q: Can you make certificate of origin (C/O) and Quality certificate?
A: Yes. If requested, certificate of origin and quality certificate can provide when goods are sent.

3) Q: Do you have CE or ISO for your products?
A: Yes, we have CE and ISO. Our products have been exported to USA and EU countries since 2006.

4) Q:Can you provide samples?
A:Yes, we'll send the sample out after sample order confirmed.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier